COVID-19 Disinfection
Sterilization and Disinfection Booth for Human
Disinfection device using dry heat
method with far-infrared(FIR)
- Disinfection device with high efficiency and reduced hesitancy
- Disinfection device using dry heat method with far-infrared
- High-temperature dry sterilizer for human body to sterilize pathogens attached on people entering and exiting a specific place at a set temperature
COVID-19 and Influenza A virus were inactivated over 99.999%
Virus inactivation conditions
BSL3 LAB test reports and academic research
-
Pathogen on human |
COVID-19 VIRUS, SARS-COV-2 VIRUS ; (Severe Acute Respiratory Syndrome Coronavirus) |
75℃, 30 sec (over 99.999%) |
INFLUENZA-A VIRUS |
75℃, 30 sec (over 99.999%) |
MERS-COV ; (Middle East Respiratory Syndrome Coronavirus) |
75℃, 30 sec |
-
Pathogen on animal |
African Swine Fever (ASF) VIRUS
|
70℃, 180 sec |
Avian Influenza (AI) VIRUS |
80℃, 60 sec |
Foot and Mouth Disease (FMD) VIRUS
|
72℃, 12 sec / 76℃, 7 sec |
Differentiated disinfection method
Classification |
High-temperature dry method |
Aerosol(Spraying) method |
Ultraviolet (UV-V, C, B ,A irradiation) method |
Details |
- Effectively sterilize pathogens vulnerable to high temperature dry
- Harmless to human body
- All-weather disinfection method regardless of weather or season
- CE certification (Done)
- Prohibition on use from WHO, CDC & KDCA (None)
- BSL3 LAB certification and test reports (Done)
|
- Specific medicine is required for specific pathogens
- Maintaining the effect at the proper temperature (15~20℃)
- Difficulty of maintaining proper temperature in winter
- Disinfectant contact time (10~15 sec) is absolutely insufficient for sterilization
- Hazardous problems to humans when inhaled (Humidifier disinfectant incident, etc.)
- Prohibition on use from WHO, CDC & KDCA
- BSL LAB certification and test reports (None)
|
- Sterilized only irradiated area & light should be irradiated for a long time for sterilization
- Maintaining the UV effect at the proper temperature (Internal 40℃)
- Difficulty of maintaining proper temperature in winter
- Hazardous problems to humans when irradiated (conjunctivitis/erythema/cataract, etc.)
- Focused on lower body due to the risk of eye irradiation (Disinfection is not possible for heights of 130츠 or less)
- Prohibition on use from WHO, CDC & KDCA
- BSL LAB certification and test reports (None)
|
* You can see more content by flicking the scroll sideways.
-
Low-cost maintenance
No need for periodic maintenance
Such as replacement of disinfectant
Or UV lamp.
-
User-friendly Equipment
No special operation required for operation
It is not irritating to the body and Can reduce the user’s avoidance of disinfection.
-
All-weather disinfection equipment
No need for a person to manage the equipment
And can be used all year round regardless of the weather.
-
Perfect disinfection
As viruses are generally very vulnerable to high temperature drying.
It is possible to disinfect not only exposed areas. But also non-exposed area such as clothes, nose, ears and mouth.
VPS-3P
-
-
Classification |
VPS for 3 people |
Dimension |
3,600 X 1,520 X 2,500 mm |
Power consumption |
3phase_380V_18A_11kW |
Temperature |
Below 95°C |
Complement |
3 people/1 time |
Additional function |
Application of timer and disinfection preparation reservation system |
Complement per hour |
1 time: 3 people (30 sec + entering/exiting time 20 sec = 50 sec) 1 hour: 216 people |
VPS-10P
-
-
Classification |
VPS for 10 people |
Dimension |
5,500 X 1,950 X 2,500 mm |
Power consumption |
3phase_380V_36A_22kW |
Temperature |
Below 95°C |
Complement |
10 people/1 time |
Additional function |
Application of timer and disinfection preparation reservation system |
Complement per hour |
1 time: 10 people (30 sec + entering/exiting time 20 sec = 50 sec) 1 hour: 720 people |
VPS-M
-
-
Classification |
VPS for |
Complement |
32people/1 time |
Complement per hour |
1 time: 10 people (30 sec + entering/exiting time 20 sec = 50 sec) 1 hour: 2,304 people |